Greenheck warrants this equipment to be free from defects in material and workmanship for a period
of one year from the purchase date. Any units or parts which prove defective during the warranty
period will be replaced at our option when returned to our factory, transportation prepaid. Motors are
warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck
prove defective during this period, they should be returned to the nearest authorized motor service
station. Greenheck will not be responsible for any removal or installation costs.
As a result of our commitment to continuous improvement, Greenheck reserves the right to change
specifications without notice.
P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 greenheck.com

Our Warranty
Prepared to Support
Green Building Efforts
Greenheck delivers value
to mechanical engineers by
helping them solve virtually
any air quality challenges
their clients face with a
comprehensive selection of
top quality, innovative air-
related equipment. We offer
extra value to contractors
by providing easy-to-install,
competitively priced, reliable
products that arrive on time.
And building owners and
occupants value the energy
efficiency, low maintenance
and quiet dependable operation
they experience long after the
construction project ends.
SQ BSQ Rev. 6 April 2008 SP
Copyright © 2008 Greenheck Fan Corp.
Centrifugal Inline Guide
 centrifugal forward curved direct driven cabinet fans are for

from 70 to 3,800 cfm (120 to 6,500 m
3
/hr) and up to 1 in. wg (250 Pa) of
static pressure.
 centrifugal forward curved belt drive fans are for use in supply,
exhaust, or return air applications. Designed in a low profile cabinet
with heights ranging from 11 to 23 in. (279 to 584 mm)
from 170 to 3,330 cfm (290 to 56,00 m
3
/hr) for single fan models and
600 to 5,800 cfm (1020 to 9,900 m
3
/hr) for double fan models with up to
1.5 in. wg (370 Pa) of static pressure.
 centrifugal forward curved belt drive duct fans are designed

300 to 15,000 cfm (510 to 25,500 m
3
/hr) with up to 3 in. wg (740 Pa) of static
pressure.
 centrifugal backward inclined belt or direct drive fans


30 to 27,000 cfm (50 to 45,900 m
3
/hr)(990 Pa) of static
(82°C).
 centrifugal backward inclined belt drive fans for higher
(600 to 40,800 m
3
/hr)
(1118 Pa)
(93°C).